  99 av6 cs (av6) switches s model switch connector type features ?using a connector for connections signi?antly improves operation effec- tiveness. applicable connector: xa connector produced by jst mfg. co., ltd. - contact: sxa-001t-p0.6 - housing: xap-02v-1 ?contact reliability is achived by sim- ple dust prevension guard and gold- clad double layer contacts ?the contact arrangement is available in two types, the spst-nc and the spst-no. ?the lever position is available in two types. standard lever position "standard lever position" refers to a posi- tion in which the lever is installed with the plunger close to the reference. backward lever position "backward lever position" refers to a posi- tion in which the lever is installed with the plunger far away from the reference. connector a a a-a cross-section (internal parts omitted) (with cap removed) gold-clad copper alloy (spst-nc) gold clad double layer contacts typical applications ?detection of vending machine condi- tion whether cans are out of stock ?ball detection of pinball game ma- chine ?ppc (plain paper copier) ?lbp (laser beam printer) ordering information type of switch av6: cs switch actuators 0: 2: 4: 5: pin plunger hinge lever simulated roller lever roller lever o.f. (by pin plunger) 2: 5: 0.50 n 1.50 n contact arrangement 2: 3: spst-nc spst-no lever position nil: 12: standard backward contacts 64: gold clad double layer ex. av6 2 2 2 12 64 remarks: 1. standard packing inner carton: 100 pcs. outer carton: 1,000 pcs. 2. when ordering ul, csa and t?v approved types, please attach suffix ? to the part no.
100 av6 product types 1. lever position: standard remarks: 1. when ordering ul, csa and t?v approved (under application) types, please attach suftx "3" to the part no. actuator operating force, max. contact arrangement spst-nc spst-no pin plunger 0.50n av620264 av630264 1.50n av620564 av630564 hinge lever 0.20n av622264 av632264 0.50n av622564 av632564 simulated roller lever 0.20n av624264 av634264 0.50n av624564 av634564 roller lever 0.20n av625264 av635264 0.50n av625564 av635564 2. lever position: backward remarks: 1. when ordering ul, csa and t?v approved (under application) types, please attach suftx "3" to the part no. actuator operating force, max. contact arrangement spst-nc spst-no hinge lever 0.35n av62221264 av63221264 1.00n av62251264 av63251264 simulated roller lever 0.35n av62421264 av63421264 1.00n av62451264 av63451264 roller lever 0.35n AV62521264 av63521264 1.00n av62551264 av63551264 specifications 1. contact rating 2. characteristics contact voltage resistive load (cos ] 1) gold clad double layer 30[v] dc 0.1[a] 5[v] dc 1[ma] low-level circuit rating expected life mechanical min. 5 ? ?
101 av6 3. operating characteristics 1) lever position: standard 2) lever position: backward type of actuator operating force, max. release force, min. pretravel, max. mm inch movement differential, max, mm inch overtravel, min. mm inch operating position, mm inch pin plunger 0.50n 0.04n 0.6 .024 0.1 .004 0.4 .016 8.4 base line 2.5 0.1 .098 .004 5.7 .224 7.6 .299 3.85 .152 7 .276 2.5 .098 9.5 0.08 .374 .003 29.2 1.150 2.4 .094 + 0.05 ? 0.1 + .002 ? .004 2.4 .094 + 0.05 ? 0.1 + .002 ? .004 7.7 .303 pin plunger type p.t 0.6 .024 max. pin plunger type o.p 8.4 0.3 .331 .012 10.0 .394 pretravel, max. mm inch 0.6 .024 movement differential, max. mm inch 0.1 .004 overtravel, min. mm inch 0.4 .016 operating position distance from mounting hole, mm inch 8.4 0.3 .331 .012 2. hinge lever lever position: standard 12.9 .508 4.0 .157 7 .276 2.5 .098 o.p 10.0 0.08 .394 .003 p. t 2.6 .103 max. 2.5 0.1 .098 .004 5.7 .224 9.5 0.08 .374 .003 29.2 1.150 2.4 .094 + 0.05 ? 0.1 + .002 ? .004 2.4 .094 + 0.05 ? 0.1 + .002 ? .004 7.7 .303 10.0 .394 pretravel, max. mm inch 2.6 .102 movement differential, max. mm inch 0.8 .031 overtravel, min. mm inch 1.2 .047 operating position distance from mounting hole, mm inch 10.0 0.8 .394 .031 lever position: backward 4.0 .157 2.4 .094 7 .276 2.5 .098 o.p 9.2 0.6 .362 .024 p. t 1.4 .055 max. 2.5 0.1 .098 .004 5.7 .224 9.5 0.08 .374 .003 29.2 1.150 2.4 .094 + 0.05 ? 0.1 + .002 ? .004 2.4 .094 + 0.05 ? 0.1 + .002 ? .004 7.7 .303 10.0 .394 pretravel, max. mm inch 1.4 .055 movement differential, max. mm inch 0.6 .024 overtravel, min. mm inch 0.7 .028 operating position distance from mounting hole, mm inch 9.2 0.6 .362 .024
102 av6 3. simulated roller lever lever position: standard 12.9 .508 4.0 .157 7 .276 2.5 .098 o.p 12.2 0.8 .480 .031 p. t 2.6 .103 max. 2.5 0.1 .098 .004 5.7 .224 9.5 0.08 .374 .003 29.2 1.150 2.4 .094 + 0.05 ? 0.1 + .002 ? .004 2.4 .094 + 0.05 ? 0.1 + .002 ? .004 7.7 .303 10.0 .394 pretravel, max. mm inch 2.6 .102 movement differential, max. mm inch 0.8 .031 overtravel, min. mm inch 1.2 .047 operating position distance from mounting hole, mm inch 12.2 0.8 .480 .031 lever position: backward 4.0 .157 2.4 .094 7 .276 2.5 .098 o.p 11.3 0.6 .445 .024 p. t 1.4 .055 max. 2.5 0.1 .098 .004 5.7 .224 9.5 0.08 .374 .003 29.2 1.150 2.4 .094 + 0.05 ? 0.1 + .002 ? .004 2.4 .094 + 0.05 ? 0.1 + .002 ? .004 7.7 .303 10.0 .394 pretravel, max. mm inch 1.4 .055 movement differential, max. mm inch 0.6 .024 overtravel, min. mm inch 0.7 .028 operating position distance from mounting hole, mm inch 11.3 0.6 .445 .024 4. roller lever lever position: standard 12.9 .508 7 .276 2.5 .098 o.p 15.7 0.8 .618 .031 p. t 2.6 .103 max. 2.5 0.1 .098 .004 5.7 .224 9.5 0.08 .374 .003 29.2 1.150 2.4 .094 + 0.05 ? 0.1 + .002 ? .004 2.4 .094 + 0.05 ? 0.1 + .002 ? .004 7.7 .303 10.0 .394 pretravel, max. mm inch 2.6 .102 movement differential, max. mm inch 0.8 .031 overtravel, min. mm inch 1.2 .047 operating position distance from mounting hole, mm inch 15.7 0.8 .618 .031 lever position: backward 2.4 .094 7 .276 2.5 .098 o.p 14.9 0.6 .587 .024 p. t 1.4 .055 max. 2.5 0.1 .098 .004 5.7 .224 9.5 0.08 .374 .003 29.2 1.150 2.4 .094 + 0.05 ? 0.1 + .002 ? .004 2.4 .094 + 0.05 ? 0.1 + .002 ? .004 7.7 .303 10.0 .394 pretravel, max. mm inch 1.4 .055 movement differential, max. mm inch 0.6 .024 overtravel, min. mm inch 0.7 .028 operating position distance from mounting hole, mm inch 14.9 0.6 .587 .024 mm inch general tolerance: 0.25 .010
103 av6 notes 1. fastening of the switch body 1) use ? at t lister head m2.3 screws to mount switches with less than a 0.29n m torque. use of screws washers or adhe- sive lock is recommended to prevent loos- ening of the screws. 2) check insulation distance between ground and each terminal. 3) when the operation object is in the free position, force should not be applied di- rectly to the actuator or pin plunger. also force should be applied to the pin plunger from vertical direction to the switch. 4) in setting the movement after opera- tion, the over-travel should be set more than 70% as a standard. with the lever type, do not apply exces- sive force in the direction opposite to the movement, or from the horizontal direc- tion. 5) for a lever type, the force from the re- verse to the operation direction should not be applied. 2. about the connector 1) the connector on the cs switch is de- signed to t t with the xa connector pro- duced by jst mfg. co., ltd. do not use any connector other than the speci t ed connector, or solder the terminals directly. 2) make sure leads are arranged so that no constant force is applied to them when the connectors are mated. 3) keep the connector straight when in- serting it. if it is inserted at an angle, it may snag near the entrance, or it may be inserted too forcefully. 4) problems thought to be caused by the xa connector, which is speci t ed as con- forming to the cs switch connector, are not covered by the warranty. please con- tact jst mfg., co., ltd. and request coop- eration in resolving the problem. 3. selection of the switch when specifying the switch, allow 20% to the listed operating characteristics. 4. environment avoid using the switches in the following conditions; in corrosive gases, such as silicon gas in a dusty environment when cleaning the switch, use a diluted form of a neutral cleaning agent. using acidic or alkali solvents can adversely af- fect the performance of the switch. 5. precautions concerning circuits the cs switch is designed speci t cally for low-voltage, low-current loads. avoid us- ing it at loads that exceed the resistive load. 6. quality check under actual loading conditions to assure reliability, check the switch un- der actual loading conditions. avoid any situation that may adversely affect switch- ing performance.


▲Up To Search▲   

 
Price & Availability of AV62521264

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X